Customization: | Available |
---|---|
After-sales Service: | 2 Years |
Warranty: | 18 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main power
|
AC220V 50HZ / DC24V
|
|
Power consumption
|
<15W (And set with sensor supporting power consumption )
|
|
Display and push buttons
|
The big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as
alarm display ,four thin-film touch nubs ,which is used to data set . |
|
Accumulator
|
Forward total quantity ,reverse total quantity
|
|
Output signal |
Analog output |
Bi-direction with two ways ,Isolation 0-10mA/4-20mA
|
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω
|
||
Frequency output
|
Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max
output and the max output current is 50Ma when the transistor is turned on |
|
Alarm output |
Two outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower
than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. |
|
Pulse output |
For pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of
pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on . |
|
Accuracy
|
±0.5% of the value displayed ,±0.3% or ±0.2% are selectable.
|
|
Damping time constant
|
Continuous variable from 0-100 s (90%)can be selected by group
|
|
Communication
|
RS232 ,RS485 or HART Communication are selectable ,with lighting resistance
|
|
Power failure
|
An anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years)
|
|
Protection class
|
IP65
|
|
Ex-proof Mark
|
Exd IIBT4
|
1.Q:What kind of products do you offer ?
Jingbo is a high-tech enterprise specializing in manufacture flow instruments. The main products are electromagnetic flow meter, vortex flow meter, temperature and pressure compensation vortex flow meter, orifice flow meter, liquid turbine flow meter, gas turbine flow meter Meters and other products.
2.Q: Are you manufacturer or trading company ?
We are a manufacturer and assure the produce quality and short delivery time.
3. Q:How about the delivery time ?
1-3 days for normal models. For big orders, it will take about 10-15 days.
4.Q: What kind of quality guarantees do you offer?
The product warranty is 18months. And the professional technicans could solve your any problems.
5.Q: Can you make customized products or provide OEM order?
A: Yes, Both them are accept, please contact us for specific requirements.